The SIMATIC Drive Controller supports isochronous mode for the following clock systems:
PROFINET IO interface X150
PROFIBUS DP interface X126
Technology I/Os X142
With PROFIdrive Integrated
You can operate the clock systems separately or coupled on an isochronous basis. Exception: Isochronous coupling of the PROFIBUS DP interface is not possible. You can find information on the combinations in which you can couple the clock systems in Overview of isochronous mode.
You make the required settings in the relevant clock systems.
Once you have set and, if necessary, coupled the clock systems, you need to couple the OB servo with the clock system in which you wish to operate the drives / that is the leading clock system.
Proceed as follows to set the clock system of the SINAMICS Integrated:
Switch to the network view.
Click on PROFIdrive Integrated in the network view.
Make the settings for the SINAMICS Integrated under "Constant bus cycle time".
The SINAMICS Integrated is always isochronous (option is always selected).
圖片: SINAMICS Integrated (PROFIdrive Integrated) clock system
Adjust other settings if required – for example times Ti/To for reading in/outputting data in isochronous mode.
列表: Setting options for "Cycle time" in the SINAMICS Integrated clock system
Setting options | Note |
---|---|
Manual | With these settings, you operate the SINAMICS Integrated as an independent clock system. |
Automatic minimum | |
Use local send clock [X142] | With this setting, you operate the SINAMICS Integrated in isochronous mode coupled with the clock system of the X142 technology I/Os. Use this setting if you want to use the technology I/Os isochronously with the OB servo, for example, for measuring input or output cam applications. Please note the following: You cannot operate the X142 technology I/Os in isochronous mode separately from SINAMICS Integrated. If you want to operate X142 technology I/Os and SINAMICS Integrated in isochronous mode simultaneously, always set coupled isochronous mode. Consistency checks ensure that the setting is correct. |
Send clock of the PROFINET interface [X150] | With this setting, you operate SINAMICS Integrated in isochronous mode coupled with PROFINET interface X150. SINAMICS Integrated uses the system clock of PROFINET interface X150. Use this setting if you need to operate the SIMATIC Drive Controller in isochronous mode at PROFINET IO interface X150, for example, for the connection of drives or for synchronous operation across PLC. |
Proceed as follows to set the clock system of the X142 technology I/Os:
In the device view of STEP 7, select the CPU of the SIMATIC Drive Controller.
Navigate to "Advanced configuration" > "Isochronous mode" in the properties of the CPU.
Select the required settings from the "Source of send clock" drop-down list in the "Isochronous mode for local modules" section.
圖片: Technology I/O clock system
列表: Setting options for "Source of send clock" in the clock system of the technology I/Os
Setting options | Note |
---|---|
Local send clock | With this setting, you operate the X142 technology I/Os as an independent clock system, or as the leading clock system if you couple the clock system of the SINAMICS Integrated. |
Using the send clock of the PROFINET interface [X150] | With this setting, you operate X142 technology I/Os in isochronous mode coupled with PROFINET interface X150. The X142 technology I/Os use the system clock of PROFINET interface X150. |
Proceed as follows to set the clock system of PROFINET interface X150:
Select the PROFINET IO system in the network view of STEP 7.
Make the settings for the send clock, etc. under "PROFINET subnet" > "Domain management" > "Sync domains".
In coupled isochronous mode with other clock systems, the clock system of the PROFINET interface is always leading.
You can find additional information on configuring isochronous mode on PROFINET IO in the Isochronous mode function manual.
You must follow the rules below during configuration if you want to operate the PROFIBUS DP interface in isochronous mode:
列表: Rules for configuring isochronous mode for PROFIBUS DP interface
If ... | The configured cycle time of the PROFIBUS DP interface must... |
---|---|
A SINAMICS Integrated is configured | Be equal to or an integer multiple of the configured cycle time of the SINAMICS Integrated (PROFIdrive Integrated) |
The X142 technology I/Os are operated in isochronous mode | Be equal to or an integer multiple of the configured cycle time of the X142 technology I/Os |
The clock system of the PROFINET IO interface is coupled with one of the two clock systems. | Be equal to or an integer multiple of the configured cycle time of the PROFINET IO interface |
Consistency checks ensure that the setting is correct.
Proceed as follows to set the clock system of the PROFIBUS interface:
Select the DP master system in the network view of STEP 7.
Make the settings for the DP cycle under "Constant bus cycle time".
提示 Isochronous coupling of the PROFIBUS interface with other clock systems is not possible. If you want to expand the drive configuration limits with distributed drive systems, connect those distributed drive systems over the PROFINET IO interface X150. Only the PROFINET IO interface X150 can be connected isochronously alongside the MC Servo to the clock system of SINAMICS Integrated and the X142 technology I/Os. |
Proceed as follows to synchronize the MC Servo with a clock system:
Open the "Program blocks" folder in the project tree.
Select the "MC Servo" organization block.
Select the "Properties" command in the shortcut menu.
Select the "Cycle time" entry in the area navigation.
The option "Synchronous to the bus" must be selected in the dialog box.
In the "Source of send clock" drop-down list, select the clock system to be synchronized with the OB MC?Servo.
圖片: Synchronizing MC Servo with clock system
列表: Setting options for synchronization with a clock system
Setting options1) | Note |
---|---|
PROFIdrive system (1) | With this setting, you synchronize MC Servo with the clock system of SINAMICS Integrated. |
PROFINET IO system (100) | With this setting, you synchronize MC Servo with PROFINET interface X150. |
PLC_1 (0) | With this setting, you synchronize MC Servo with the clock system of technology I/Os X142. |
DP master system (2) | With this setting, you synchronize MC Servo with PROFIBUS interface X126. |
For coupled isochronous mode, you must always select the leading clock system.
The application cycle of MC Servo is derived from the send clock and a configurable factor. The adjustable factors depend on the coupled clock system.
詞條
詞條說明
TIA Portal Teamcenter Gateway 的許可授權(quán)
許可證TIA Portal Teamcenter Gateway 的許可授權(quán)要運行 TIA Portal Teamcenter Gateway,每個安裝了 TIA Portal Teamcenter Gateway 的設(shè)備上都需要具有有效的許可密鑰。即使該設(shè)備上安裝有 TIA Portal,也需要具有許可密鑰。許可密鑰可包含在安裝中,也可在安裝后通過 Automation License Mana
管理用戶和角色簡介激活證書管理器的全局安全設(shè)置后,必須登錄全局安全設(shè)置,或者您需具備管理員權(quán)限。否則,您沒有足夠的用戶權(quán)限來編輯全局證書。如果您不登錄或者您沒有足夠的權(quán)限,則您無法訪問全局證書管理器。角色和權(quán)限如果為您分配了預(yù)定義的角色“管理員”(Administrator) 或“標(biāo)準(zhǔn)”(Standard),或者為您分配了具有相關(guān)授權(quán)的其它已定義角色,則您可以組態(tài)安全設(shè)置。您可以在項目樹的“全局安
S7-1200的定時器為IEC定時器,用戶程序中可以使用的定時器數(shù)量僅僅受CPU的存儲器容量限制。使用定時器需要使用定時器相關(guān)的背景數(shù)據(jù)塊或者數(shù)據(jù)類型為IEC_TIMER(或TP_TIME、TON_TIME、TOF_TIME、TONR_TIME)的DB塊變量,不同的上述變量代表著不同的定時器。注:S7-1200的IEC定時器沒有定時器號(即沒有T0、T37這種帶定時器號的定時器)。S7-1200包
配置SIMATIC NET的OPC 服務(wù)器的符號訪問
場景1:OPC客戶端利用SIAMTIC NET作為OPC 服務(wù)器訪問S7-200 SMART時,通常需要在客戶端或者OPC SCOUT V10建立大量變量,地址的大部分都是諸如"S7:[S7_Connection_1]"重復(fù)字段。場景2:不同項目使用相同或接近的變量表時,需要重新錄入大量變量。以上場景均可以利用SIAMTIC NET的符號表功能簡化操作,并使用EXCEL來完成重復(fù)性的工作,使得配置
公司名: 上海騰希電氣技術(shù)有限公司
聯(lián)系人: 田禮科
電 話: 021-37660026
手 機: 13681875601
微 信: 13681875601
地 址: 上海松江上海市松江區(qū)廣富林路4855弄星月大業(yè)**88號4樓
郵 編:
網(wǎng) 址: shtxjd.cn.b2b168.com
公司名: 上海騰希電氣技術(shù)有限公司
聯(lián)系人: 田禮科
手 機: 13681875601
電 話: 021-37660026
地 址: 上海松江上海市松江區(qū)廣富林路4855弄星月大業(yè)**88號4樓
郵 編:
網(wǎng) 址: shtxjd.cn.b2b168.com