When you create a kinematics technology object as of V5.0 for S7-1500T Motion Control, the organization block MC?LookAhead [OB97] is created automatically.
The movement preparation of the kinematics technology object is calculated in the MC?LookAhead [OB97] organization block.
The MC?LookAhead [OB97] is write-protected. The contents cannot be changed.
提示 Only one MC?LookAhead [OB97] per CPUThe movements of all kinematics of a CPU are prepared in an MC?LookAhead [OB97] organization block. The MC?LookAhead [OB97] can only be created once. |
All jobs of the job sequence are prepared in advance within the MC?LookAhead [OB97]. In this way, less time is required for movement preparation in the MC?Interpolator [OB92] organization block and you can set a shorter application cycle of the MC?Servo [OB91] organization block.
The MC?LookAhead [OB97] is not called cyclically according to the configured priority in the execution system of the CPU.
You configure the priority of the MC?LookAhead [OB97] in the properties of the organization block under "General > Attributes > Priority". You can set values from 14 to 16 (default setting 15) for the priority. The priority of MC?LookAhead [OB97] must be lower than the priority of MC?Interpolator [OB92].
You can configure the maximum cycle load for the MC?LookAhead [OB97].
You configure the maximum cycle load of the MC?LookAhead [OB97] in the properties of the organization block under "General > Cycle load > Maximum cycle load". You can set values from 1% to 40% (default setting 20%) for the maximum cycle load.
Select the cycle load of the MC?LookAhead [OB97] in such a way that the CPU can process all technology objects for Motion Control in one application cycle.
If the application cycle is not observed, overflows occur. Note the following response to overflows:
The CPU tolerates a maximum of three consecutive overflows of MC?Interpolator [OB92].
The execution of an MC?Interpolator [OB92] may only be interrupted by an MC?Servo [OB91] call.
If more overflows or interruptions occur, the CPU switches to STOP mode.
You can find more information on the process response in the section "Operational Sequence and Timeouts".
詞條
詞條說明
導出文件的 XML 模式導出文件的 XML 模式根據(jù)以下模式,組織模塊標簽條的 XML 文件: 大家可能會非常熟悉RS232,RS485,CAN等工業(yè)上常用的總線,他們都是傳輸數(shù)字信號的方式。那么,我們用什么方式來傳輸模擬信號呢?工業(yè)上普遍需要測量各類非電物理量,例如溫度、壓力、速度、角度等,這些都需要轉換成模擬量電信號才能傳輸?shù)綆装倜淄獾目刂剖一蝻@示設備上。工業(yè)上較廣泛采用的是用4~20mA電流來傳輸模擬量。采用電流信號的原因是不容易受干擾,因為工業(yè)現(xiàn)場的噪聲電壓的幅度可能達到數(shù)V,但是噪
在 Web 頁面中使用 AWP 命令借助 AWP(Web 自動編程)命令,可聲明用戶頁面(Web 應用程序,例如,某個簡單的 HTML 頁面)和 CPU 數(shù)據(jù)之間的接口。若要開發(fā)用戶頁面或 Web 應用程序,則僅需注意 Web 瀏覽器的限制條件即可。在某種 STEP 7 編程語言中,可通過 CPU 中的用戶程序控制 Web 瀏覽器中顯示的 CPU 數(shù)據(jù)以及這些數(shù)據(jù)的顯示時間。通過為 HTML 頁面
Step7 組態(tài)PC Station 與 S7-1200 基于以太網的S7 通信
硬件需求和軟件需求硬件:① S7 1200 CPU② PC (帶普通以太網卡)③ TP線軟件:① STEP 7 Basic V10.5② STEP 7 V5.4③ SIMATIC NET V7.1STEP7中組態(tài)PC Station1. 在STEP7 中新建項目,組態(tài)PC Station。打開STEP7并新建一個項目:“S7-1200_OPC”,通過“Insert”>“Station”>
公司名: 上海騰希電氣技術有限公司
聯(lián)系人: 田禮科
電 話: 021-37660026
手 機: 13681875601
微 信: 13681875601
地 址: 上海松江上海市松江區(qū)廣富林路4855弄星月大業(yè)**88號4樓
郵 編:
網 址: shtxjd.cn.b2b168.com
公司名: 上海騰希電氣技術有限公司
聯(lián)系人: 田禮科
手 機: 13681875601
電 話: 021-37660026
地 址: 上海松江上海市松江區(qū)廣富林路4855弄星月大業(yè)**88號4樓
郵 編:
網 址: shtxjd.cn.b2b168.com