1. 概述
Overview
在工業(yè)應(yīng)用中,剩余電流繼電器與外部剩余電流互感器結(jié)合使用以檢測和評估接地故障電流。它們也可以與保護(hù)裝置結(jié)合使用,以實(shí)現(xiàn)電路的斷開,從而實(shí)現(xiàn)對線路和人員的保護(hù)。
Residual current relay can be combined with external residual current transformer to detect and evaluate the ground fault current. They can also be combined with protective devices to realize the disconnection of circuits and the protection of lines and workers.
2.剩余電流的定義以及危害
Definition and risk of residual current
剩余電流,是指低壓配電線路中各相(含中性線)電流矢量和不為零的電流。通俗講當(dāng)用電側(cè)發(fā)生了事故,電流從帶電體通過人體流到大地,使主電路進(jìn)出線中的電流I相和I中的大小不相等,此時(shí)電流的瞬時(shí)矢量合成有效值稱為剩余電流,俗稱漏電。
Residual current is the current vector sum of each phase (including the neutral ) in the low-voltage distribution that not be zero. Generally, when there is an accident on the power side, the current flows from the charged body to the earth through the human body,it will cause that the current phase I in the main circuit not equal to the size in phase I. At this time, the value of instantaneous current vector synthesis is called residual current, commonly known as leakage.
TN System
3.剩余電流的危害:
Risk of residual current:
人身觸電。當(dāng)電氣設(shè)備因絕緣損壞而使外殼帶電,而工作人員又接觸此外殼時(shí),就會導(dǎo)致人身觸電事故。
(1)Physical electric shock. When shell of the electrical equipment is electrified due to insulation damage, and the workers touch the shell again, it will lead to physical electric shock accident.
燒損電氣設(shè)備,引起火災(zāi)。長期存在的漏電電流,尤其是兩相經(jīng)過電阻接地的漏電電流,在通過設(shè)備絕緣損壞處時(shí)將散發(fā)出大量的熱,使絕緣進(jìn)一步損壞,甚至使可燃性材料(如非阻燃性橡套電纜)著火燃燒。
Burn electrical equipment and cause fire. The long-term leakage current, especially the leakage current of two-phase grounded through resistance, will release a lot of heat when flow through the damaged part of the equipment insulation, further damaging the insulation, and even making combustible materials (such as non flame retardant rubber sheathed cable) burn on fire.
引起短路事故。據(jù)統(tǒng)計(jì),約有30%的單相接地故障發(fā)展為短路。從而造成較大的電氣故障。長期存在的漏電電流及電火花使漏電處的絕緣進(jìn)一步損壞,后危及相間絕緣而造成短路。
(3) Cause short circuit accident. According to statistics, about 30% of single-phase grounded faults develop into short circuit which will give rise to heavier electrical failure. The long-term leakage current and spark further damage the insulation at the leakage point, and finally endanger the interphase insulation and cause short circuit.
引起電氣火災(zāi)事故。電網(wǎng)發(fā)生單相接地或設(shè)備發(fā)生單相碰殼時(shí),在接地點(diǎn)就會產(chǎn)生電火花,若此電火花具有足夠的能量,就可能點(diǎn)燃易燃易爆物品。
Cause electrical fire accident. When the single-phase grounding occurs in the power grid or the single-phase collision occurs in the equipment, the electric spark will be generated at the grounding point. If the electric spark has enough energy, it may ignite flammable and explosive materials.
4.如何測剩余電流
How to measure residual current
在被測的三相導(dǎo)線路上與N線上各裝一個(gè)CT,或讓三相導(dǎo)線與N線一起穿過一個(gè)零序CT,得到三相導(dǎo)線與中性線N的電流矢量和IA*+IB*+IC*+IN*,當(dāng)沒有發(fā)生單相接地故障時(shí),無論三相負(fù)荷平衡與否,則此矢量和為零;當(dāng)發(fā)生某一相接地故障時(shí),故障電流中會通過保護(hù)PE及與地相關(guān)連的金屬構(gòu)件回到電源,即IA*+IB*+IC*+IN*,此時(shí)數(shù)值為接地故障電流Id。
Installing a CT on each of the three-phase conducting lines to be tested and N line or let the three-phase conductor and the n-line pass through a zero sequence CT together to get the current vector sum IA * + IB * + IC * + IN * . when there is no single-phase grounded fault, whether the three-phase load is balanced or not, the vector sum is zero; when there is a phase grounded fault, the fault current will flow through the protection PE and the metal components connected to the earth to the power supply, at this time, the value is the ground fault current Id.
5.ASJ系列剩余電流動(dòng)作繼電器
ASJ series residual current operated relay
ASJ系列剩余電流動(dòng)作繼電器可與低壓斷路器或低壓接觸器等組成組合式剩余電流保護(hù)裝置, 主要適用于交流 50Hz, 額定電壓 400V 及以下的 TT 和 TN 系統(tǒng)配電線路, 用來對電氣線路進(jìn)行接地故障保護(hù), 防止接地故障電流引起的設(shè)備損壞和電氣火災(zāi)事故, 也可用來對人身觸電危險(xiǎn)提供間接接觸保護(hù)。
ASJ series residual current action relay can be combined with low voltage circuit breaker or low voltage contactor to form a combined residual current protection device.It is mainly used for TT and TN system distribution lines with AC 50Hz and rated voltage of 400V and below.It is used to protect the electrical circuit from ground faults, prevent equipment damage caused by ground fault current and electrical fire accidents, and can also be used to provide indirect contact protection against personal electric shock hazard
詞條
詞條說明
ARD3M智能電動(dòng)機(jī)保護(hù)器在河南心連心化學(xué)工業(yè)集團(tuán)的應(yīng)用
摘要:介紹安科瑞ARD3M智能電動(dòng)機(jī)保護(hù)器在河南心連心化學(xué)工業(yè)集團(tuán)年產(chǎn)40萬噸雙氧水項(xiàng)目的應(yīng)用。用于新建40萬噸雙氧水項(xiàng)目廠區(qū)內(nèi)電動(dòng)機(jī)回路的參數(shù)測量、故障保護(hù)、起停控制以及后臺通訊,為該車間的安全、穩(wěn)定生產(chǎn)保駕**關(guān)鍵詞:河南心連心、ARD3M、電動(dòng)機(jī)保護(hù)器項(xiàng)目概述:心連心化學(xué)工業(yè)集團(tuán)位于河南省新鄉(xiāng)市新鄉(xiāng)縣,是一家致力于化肥、基礎(chǔ)化學(xué)的大型化工集團(tuán)。本項(xiàng)目為心連心新建年產(chǎn)40萬噸雙氧水項(xiàng)目一期,所
Acrel-2000Z電力監(jiān)控系統(tǒng)在某區(qū)塊頁巖氣地面集輸工程中的應(yīng)用
摘要:Acrel-2000Z電力監(jiān)控系統(tǒng)適用于35kV及以下電壓等級的各類變電站,可以幫助用戶掌握配電系統(tǒng)實(shí)時(shí)運(yùn)行狀態(tài),獲取預(yù)警、告警等各類事件,實(shí)現(xiàn)著重區(qū)域的**,提高安全監(jiān)管水平。本文介紹了安科瑞電力監(jiān)控系統(tǒng)Acrel-2000在某區(qū)塊頁巖氣地面集輸工程中的應(yīng)用,該系統(tǒng)實(shí)現(xiàn)了分布式采集和集中控制的智能化管理,為工程中設(shè)備安全、可靠、合理的進(jìn)行生產(chǎn)提供了堅(jiān)實(shí)的技術(shù)**,亦給其開展節(jié)能減排工作
Acrel-5000能耗管理系統(tǒng)在常德市民之家的應(yīng)用
摘要:近年來工廠、企業(yè)等項(xiàng)目的不斷建設(shè),同時(shí),IT集成化技術(shù)、網(wǎng)絡(luò)技術(shù)、現(xiàn)場總線技術(shù)的不斷發(fā)展也不斷推動(dòng)了智能化系統(tǒng)的快速發(fā)展。在企業(yè)內(nèi),水、電、氣是日常運(yùn)行不可缺少的**,然而對于管理人員來說,每個(gè)月手工抄取各個(gè)用戶及設(shè)備的能耗讀數(shù)卻是非常繁重的工作,需要投入大量的人力和物力。為解決智能化工程對水、電、氣的自動(dòng)采集、記錄、分析、報(bào)表等問題,通過設(shè)計(jì)一套能耗管理系統(tǒng),將這些*立的檢測儀表納入到一個(gè)
關(guān)于有源電力濾波器在地鐵站低壓配電系統(tǒng)中的應(yīng)用分析
摘要:作為國家提出的綠色電網(wǎng)、節(jié)能降耗已成為現(xiàn)代化企業(yè)努力的目標(biāo),也是企業(yè)急需解決的問題。作為地鐵車站這類**公共交通建筑的著重系統(tǒng)——配電系統(tǒng)。實(shí)現(xiàn)綠色電網(wǎng)實(shí)質(zhì)上是解決電網(wǎng)中存在的各種電能問題,主要是涉及到諧波與無功問題兩個(gè)方面,就某條地鐵線目前的電力系統(tǒng)狀態(tài)而言,其在低壓配電系統(tǒng)中裝設(shè)有源電力濾波器進(jìn)行諧波治理,但APF實(shí)際未投入。系統(tǒng)中的諧波問題仍然存在,因此需對該站點(diǎn)進(jìn)行詳細(xì)的測試,同時(shí)為
公司名: 江蘇安科瑞電器制造有限公司
聯(lián)系人: 劉川
電 話: 18861632831
手 機(jī): 18861632831
微 信: 18861632831
地 址: 江蘇無錫江陰市南閘東盟東業(yè)園區(qū)東盟路5號
郵 編:
網(wǎng) 址: zyjacrel.cn.b2b168.com
公司名: 江蘇安科瑞電器制造有限公司