1. 應(yīng)用場景Application Scenario
對工廠的三相用電設(shè)備的用電量進行采集并上傳至系統(tǒng), 從而使用戶能夠?qū)崿F(xiàn)在PC上就能通過IoT EMS系統(tǒng)查看設(shè)備用電情況。
Customers need to collect the basic energy consumption data and upload it to management system so that they can realized real-time and remote data monitoring using their PC.
2. 技術(shù)選型 Technical Selection
2.1三相回路電壓為415Vac L-L,額定電流不**過80A AC,三相四線接線,電表方面選型三相帶RS485(MODBUS-RTU)通訊的電表ADL400。
Rated voltage of 3-phase monitoring circuits is 415Vac L-L while the rated current is below 80A AC, thus selection of metering devices will be ADL400 3-phase energy meter with RS485 communication of MODBUS-RTU protocol
2.2工廠經(jīng)確認后WiFi覆蓋條件較好,頻段為2.4GHz,方便提供220Vac供電,網(wǎng)關(guān)選用AWT100-WiFi搭配POW模塊。支持廣播自動抄表以便后續(xù)下行設(shè)備的添加。該網(wǎng)關(guān)上行為4GHz WiFi,采用MODBUS-RTU over TCP的透傳通訊協(xié)議。下行為RS485通訊,采用MODBUS-RTU協(xié)議,從而與ADL400配合對數(shù)據(jù)進行上傳至云服務(wù)器通向系統(tǒng)。
After discussing with the customer, factory is with stable 4GHz WiFi coverage and **,and a power supply of 220Vac is preferable. So, for the gateway parts, we select AWT100-WiFi which own auto-broadcasting function that can ease the later adjustment with subsequent ADL400. Also, AWT100-WiFi is paired with AWT100-POW power module.Other than that, since AWT100-WiFi is with upstream of 2.4GHz WiFi using MODBUS-RTU over TCP protocol and downstream of RS485 using MODBUS-RTU protocol to be paired with ADL400 for energy consumption data uploaded to cloud server and finally to the IoT System.
2.3測試階段服務(wù)器使用我司已經(jīng)租用的亞馬遜云服務(wù)器以節(jié)省客戶預(yù)算。
For pilot project phase, cloud server is highly recommended to use our company’s cloud server which has been rent on Amazon to save the customers’ budget on testing phase.
2.4根據(jù)需求系統(tǒng)選用IoT EMS系統(tǒng),并提供3個月試用以便客戶測試。
According to the request, IoT Energy Management System will be the most appropriate one and can provide 3-month free trial for testing use.
3. 初期方案架構(gòu)Pilot Project Solution Structure
4. 后期方案方向 Plan after Pilot Project
若初期方案測試成功,后期方案方向為:
If pilot project proved to be successful, later plan should be as below:
4.1云托管方案:綜合考慮云服務(wù)器租用成本以及點位數(shù)量不多的情況,云方案推薦為系統(tǒng)軟件選用托管,云服務(wù)器依舊使用我司的云服務(wù)器。硬件設(shè)備層*改動,只需后續(xù)增訂ADL400三相電能表,若點位數(shù)量需求較多,根據(jù)情況配套增訂AWT100-WiFi網(wǎng)關(guān)。
Cloud Hosting Service Solution: Considering about the comprehensive cost of renting the cloud server and the amount of monitoring circuits, deployment of cloud IoT Energy Management System should be paired with hosting service. In this situation, customer don’t need to afford the rent of cloud server and will use our own cloud server. Also, for the hardware of this solution, no change need be done just like in the pilot project solution structure. Customer only need to order more ADL400 3-phase energy meter and maybe paired AWT100-WiFi gateway according to the number of subsequent request.
4.2本地買斷方案:若客戶對數(shù)據(jù)保密性比較有想法,后期推薦方向為IoT系統(tǒng)買斷服務(wù),服務(wù)器架設(shè)本地服務(wù)器并搭配工業(yè)交換機與UPS電源。硬件設(shè)備層電表依舊推薦ADL400,特殊型號ADF400L不推薦使用,原因是在三相四線接線為直通式接線而非互感器接入時,ADF400L的測量模塊需求數(shù)量較多,無法減少成本。網(wǎng)關(guān)方面根據(jù)后期點位數(shù)量增配AWT100-CE或者APort100.
Local Buy-out Service Solution: If request from customers for data safety and Confidentiality is much more higher. The buy-out service of IoT Energy Management System to be paired with a Local Server will be the best choice. Yet the solution need to do a lot of change in hardware like. First, deploying of local server need to be paired with industrial switch and UPS. Second, for energy meter, ADL400 is still more recommendable.Since the special module, ADF400L Multi-circuit energy meter with built-in Ethernet communication won’t save much budget on the application of 3-phase wiring via direct connection instead of via CTs. At last, gateway need to be changed from AWT100-WiFi to AWT100-CE or Aport100 according to the amount of subsequent request.
5. 后期方案架構(gòu) (僅指采用本地方案的情況下) Late-stage Solution Structure (For local solution only)
相關(guān)產(chǎn)品:多功能電表、導(dǎo)軌式智能電表、無線電表、4G電表、NB電表、電機保護器、馬達保護器、線路保護器、預(yù)付費電表、無線測溫、電房**系統(tǒng)、配電室綜合監(jiān)控系統(tǒng)、電能管理系統(tǒng)、能耗管理系統(tǒng)、用電管理系統(tǒng)、能源信息化系統(tǒng)、預(yù)付費管理系統(tǒng)
詞條
詞條說明
能耗的計量、監(jiān)測與管理,是實現(xiàn)節(jié)能減排的基礎(chǔ)?;谖锫?lián)網(wǎng)的能耗管理系統(tǒng),就是通過互聯(lián)網(wǎng)對各類能耗實行精細計量、實時監(jiān)測、智能處理和動態(tài)管控,達到精細化管理的目標。該系統(tǒng)適用于公共機構(gòu)、工礦企業(yè)、通信、交通、學(xué)校、園區(qū)、村鄉(xiāng)鎮(zhèn)、住宅群等實現(xiàn)全面的能耗計量、監(jiān)測、控制和管理,也能夠滿足各級**的能源主管部門以及能源審計、評估、公正等第三方監(jiān)管機構(gòu)對加強用能管理、落實節(jié)能措施、開展節(jié)能工作、實現(xiàn)節(jié)能目標
10月3日,浙江省發(fā)布《浙江省關(guān)于建立健全高耗能行業(yè)階梯電價和單位產(chǎn)品**能耗限額標準懲罰性電價的實施意見(征求意見稿)》。意見明確了八大高耗能行業(yè)列入了階梯電價加價范圍,包括紡織、非金屬礦物制品業(yè)、金屬冶煉及壓延加工業(yè)、化學(xué)原料及化學(xué)制品制造業(yè)、石油煤炭及其他燃料加工、造紙和紙制品、化學(xué)纖維制造、電力熱力的生產(chǎn)和供應(yīng)業(yè),浙江本次將“數(shù)據(jù)中心”作為階梯電價加價范疇。另外明確**限額電價檔次和執(zhí)行標準:
大家都知道,雷雨天氣雷擊對大家造成的干擾和毀壞是十分較大的,因而對于各種各樣開關(guān)電源家用電器設(shè)備,搞好對應(yīng)的防雷對策也是十分**的。伴隨著當代防雷技術(shù)性的不斷發(fā)展,防雷商品也在持續(xù)的破舊立新,浪涌保護器做為一種技術(shù)專業(yè)防雷器,近些年遭受了很多消費者的關(guān)心。浪涌保護器,也叫防雷器,是一種為各種各樣電子器件設(shè)備、儀表設(shè)備、通信線路給予安全防護的電子系統(tǒng)。當電氣設(shè)備控制回路或是通訊線路中由于外部的影響忽
消防應(yīng)急疏散指示系統(tǒng)在某廣場住宅區(qū)項目的應(yīng)用
【摘要】:消防應(yīng)急照明和疏散指示系統(tǒng)由控制器、集中電源和燈具(疏散指示燈具、應(yīng)急照明燈具)等幾部分組成。系統(tǒng)采用17寸工業(yè)平板電腦、Windonws7系統(tǒng),可支持聯(lián)動報警、系統(tǒng)監(jiān)控、故障報警、自檢、備電、記錄存儲與查詢、導(dǎo)光流、權(quán)限控制等多項功能,具有集中控制、靈活度高和可靠性強等特點。配合標志燈與應(yīng)急照明燈具,適用于區(qū)域內(nèi)高層建筑群,滿足范圍廣、樓層高等特點的項目。 【關(guān)鍵詞】:集中控制;消防應(yīng)