Application of Acrel Branch Circuit Power Meter in Ghana Data Center
安科瑞 陳玉茹
摘要:數(shù)據(jù)中心是一個(gè)聚集了大量服務(wù)器、存儲(chǔ)設(shè)備、網(wǎng)絡(luò)設(shè)備及配套UPS、空調(diào)等設(shè)備的IT設(shè)備場(chǎng)所,是實(shí)現(xiàn)數(shù)據(jù)信息的集中處理、存儲(chǔ)、傳輸、交換和集中管理等業(yè)務(wù)的服務(wù)平臺(tái)。
數(shù)據(jù)中心供電電源質(zhì)量的好壞直接影響到IT設(shè)備的安全運(yùn)行,因此對(duì)數(shù)據(jù)中心列頭柜電源進(jìn)出線實(shí)行監(jiān)測(cè)非常重要,另外,隨著**可用能源的減少以及能源成本的提高,如何較加經(jīng)濟(jì)和使用能源已成為相關(guān)企業(yè)責(zé)無(wú)旁貸的責(zé)任。
Abstract: Data center is a place that gathering a large number of servers, storage equipment, network equipment and supporting UPS, precision air conditioning and other IT equipment, is to realize the centralized processing, storage, transmission, exchange and centralized management of data and information service platform.
Data center power supply quality directly affects the safe operation of the IT equipment, thus the data center column header tank outlet and inlet line of power supply monitoring is very important, in addition, as the global of available energy and reduced energy costs rise, how much more economic and efficient use of energy has become a duty-bound responsibility related enterprises.
1.項(xiàng)目概述 Project overview
針對(duì)數(shù)據(jù)中心列頭柜對(duì)于監(jiān)測(cè)裝置的要求,我司設(shè)計(jì)了AMC16-FAK48數(shù)據(jù)中心監(jiān)控裝置來(lái)實(shí)現(xiàn)多路出線的電參數(shù)及進(jìn)出線開(kāi)關(guān)狀態(tài)等實(shí)現(xiàn)監(jiān)測(cè)。Maxitech是加納的數(shù)據(jù)中心解決方案供應(yīng)商,客戶有兩個(gè)柜子,分別有20個(gè)出線回路要進(jìn)行監(jiān)測(cè),同時(shí)后期還有10-20個(gè)回路會(huì)增加,所以客戶選擇了AMC16Z-FAK,它可以同時(shí)監(jiān)測(cè)48個(gè)出線回路,客戶測(cè)量電流為100A,所以搭配使用我們的AKH-0.66W-12N互感器。
According to the requirements of data center array cabinet for monitoring device, our company designed AMC16-FAK48 data center monitoring device to realize the electrical parameters of multiple outgoing lines and the switch state of incoming and outgoing lines to achieve comprehensive monitoring. Maxitech is the data center System solution provider in Ghana. The customer has two cabinets with 20 outlet loops to be monitored, and 10-20 loops will be added later, so the customer chooses AMC16Z-FAK, which can monitor 48 outlet loops at the same time. The customer's measured current is 100A, so our AKH-0.66W-12N transformer is used together.
2. 功能 Function
2.技術(shù)參數(shù)Technical Features
3.組網(wǎng)拓?fù)鋱D Network topology
4.現(xiàn)場(chǎng)圖片Photo on-site
5.結(jié)束語(yǔ)Conclusion
隨著數(shù)據(jù)中心的迅猛發(fā)展,數(shù)據(jù)中心的能耗問(wèn)題也越來(lái)越**,有關(guān)數(shù)據(jù)中心的能源管理和供配電設(shè)計(jì)已經(jīng)成為熱門(mén)問(wèn)題,可靠的數(shù)據(jù)中心配電系統(tǒng)方案,是提高數(shù)據(jù)中心電能使用效率,降低設(shè)備能耗的方式。要實(shí)現(xiàn)數(shù)據(jù)中心的節(jié)能,首先需要對(duì)每個(gè)用電負(fù)載實(shí)現(xiàn)監(jiān)測(cè),而數(shù)據(jù)中心負(fù)載回路非常的多,傳統(tǒng)的測(cè)量?jī)x表無(wú)法滿足成本、體積、安裝、施工等多方面的要求,因此需要采用適用于數(shù)據(jù)中心集中監(jiān)控要求的多回路監(jiān)控裝置。
而AMC16M是專門(mén)針對(duì)數(shù)據(jù)中心交流列頭柜開(kāi)發(fā)設(shè)計(jì)的,對(duì)此類產(chǎn)品的應(yīng)用做了深入的研究,從功能、性能、可用性、經(jīng)濟(jì)性等方面都**其他方案。
With the rapid development of data centers, the problem of energy consumption in data centers is becoming more and more prominent. Energy management and power supply and distribution design of data centers have become hot issues. Efficient and reliable data center power distribution system scheme is an effective way to improve the power use efficiency of data centers and reduce the energy consumption of equipment.To realize the energy saving of the data center, you will first need to achieve precise monitoring of each power load, the load circuit and data center very much, the traditional measuring meters can meet the cost, size, installation, construction and other aspects of requirements, so you need to use applies to data center centralized monitoring requirement of multi loop monitoring device.
The AMC16M is specially designed for array cabinet in data center. The application of this kind of product has been studied in depth, and it is superior to other schemes in terms of function, performance, availability and economy.
參考文獻(xiàn) Bibliography
1.Solutions for enterprise micro-grid system 2021.04
詞條
詞條說(shuō)明
【遠(yuǎn)程抄表系統(tǒng)】系統(tǒng)特點(diǎn)
本系統(tǒng)為實(shí)現(xiàn)實(shí)時(shí)可靠地進(jìn)行三表(電表、水表、燃?xì)獗恚?shù)據(jù)遠(yuǎn)程抄收而設(shè)計(jì)。本裝置以星型/縱線型/無(wú)線電通訊?三重網(wǎng)絡(luò)結(jié)構(gòu)實(shí)現(xiàn)遠(yuǎn)程抄表任務(wù),通過(guò)星形網(wǎng)使n個(gè)MDM(DD-862S機(jī)械式數(shù)字化電表)電表(例:n=32)與一個(gè)數(shù)據(jù)采集?器連接,數(shù)據(jù)采集器通過(guò)縱線網(wǎng)絡(luò)與電臺(tái)連接,一個(gè)縱線網(wǎng)可連接m個(gè)采集器(例m=128),因此,一個(gè)子網(wǎng)可將?nm=32×128個(gè)電表共享一個(gè)電臺(tái)
絕緣監(jiān)測(cè)系統(tǒng)設(shè)備解決方案在工廠的應(yīng)用
安科瑞? 陳玉茹摘?要:船舶電力系統(tǒng)采用交流三相三線制絕緣系統(tǒng),這種系統(tǒng)的優(yōu)點(diǎn)是當(dāng)某相對(duì)地短路時(shí)不會(huì)出現(xiàn)短路跳閘而導(dǎo)致供電中斷,從而保證了船舶供電的連續(xù)性和可靠性。隨著現(xiàn)代船舶電力系統(tǒng)容量不斷增大,電力網(wǎng)絡(luò)越來(lái)越復(fù)雜和密集,同時(shí)船舶的實(shí)際環(huán)境,如溫度、濕度、鹽霧、霉菌等條件比較惡劣,使得電力系統(tǒng)絕緣故障的發(fā)生率較高,并由此引發(fā)的火災(zāi)和相間短路的嚴(yán)重事故屢見(jiàn)不鮮。長(zhǎng)期以來(lái),限于技
直流電能表和直流微安表的區(qū)別1、區(qū)別:直流電流表的表頭一般是毫安級(jí)的,動(dòng)圈匝數(shù)少,電壓靈敏度高,再配適當(dāng)?shù)姆至髌?,?gòu)成直流電流表。直流微安表,動(dòng)圈匝數(shù)多,電流靈敏度高,一般除單獨(dú)應(yīng)用外,多用于萬(wàn)用表,和高阻電壓表。2、若預(yù)先不知道被測(cè)電流的約值,可在電路中用一只可變電阻器與安培計(jì)串聯(lián),開(kāi)始時(shí)可變電阻器電阻用較大值,電流表先用0梍3安培量程,接通電路后,再將可變電阻器電阻逐漸減小,如電流一直保持在3
【電瓶車(chē)安全充電管理系統(tǒng)】充電樁集中充電有什么好處
充電樁市場(chǎng):大趨勢(shì):相關(guān)資料顯示電動(dòng)自行車(chē)保有量已達(dá)到2.5億輛,很多小區(qū)面臨充電問(wèn)題增長(zhǎng)率高達(dá)4.4%前景廣:共享單車(chē)迅猛發(fā)展順應(yīng)共享經(jīng)濟(jì)運(yùn)營(yíng)的浪潮業(yè)定制市場(chǎng)容量,電瓶車(chē)充電是一個(gè)2000億元/年的大市場(chǎng)易推廣:市場(chǎng)大,易推廣發(fā)展,目前市場(chǎng)飽和度不足15%回報(bào)高:部署合理,利用率高的情況下,預(yù)計(jì)7個(gè)月可收回成本,以單臺(tái)設(shè)備(2個(gè)口)每天利潤(rùn)2.6元產(chǎn)品優(yōu)勢(shì):安全:*阻燃、防過(guò)充、防過(guò)載、漏電保
公司名: 江蘇安科瑞電器制造有限公司
聯(lián)系人: 陳經(jīng)理
電 話:
手 機(jī): 18860990285
微 信: 18860990285
地 址: 江蘇無(wú)錫江陰市江蘇江陰南閘東盟工業(yè)園東盟路5號(hào)
郵 編:
網(wǎng) 址: jhcj.cn.b2b168.com
公司名: 江蘇安科瑞電器制造有限公司
聯(lián)系人: 陳經(jīng)理
手 機(jī): 18860990285
電 話:
地 址: 江蘇無(wú)錫江陰市江蘇江陰南閘東盟工業(yè)園東盟路5號(hào)
郵 編:
網(wǎng) 址: jhcj.cn.b2b168.com